ENTER/EXIT PROGRAMMING MODE Codablock F Set Length 1
Product Reference Guide 137
Codablock F Set Length 1
Specifies one of the barcode lengths for Codablock F Length Control. Length 1 is the minimum
label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length
includes the barcode’s data characters only. Characters
can be set from 03 to 255 characters.
Table 6 provides some examples for setting Length 1. See page 242 for detailed instructions on
setting this feature.
Table 6. CODABLOCK F Length 1 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
03 Characters 07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT CODABLOCK F LENGTH 1 SETTING
4
Scan Three Characters From
Appendix D, Keypad
‘0’, ‘0’ and ‘3’ ‘0’, ‘0’ and ‘7’ ‘0’,‘1’ and ‘5’ ‘0’,‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
Select Codablock F Length 1 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the
entry string. You can then start again at the beginning.
CANCEL
DEFAULT
03 = Length 1 is 3 Characters